Install a casing corner piece in the upright casing and insert it into the header casing.
Timely prefinished steel door frames installation instructions.
Available in both door sizes.
Align the miter and snap the upright casing over one clip at the top.
When installing the timely frame in a steel stud wall the frame must be 1 8 wider than the stud size because the stud actually rests in a track section that is 1 8 larger than the stud dimension.
Fasten the remainder of the strike jamb at every clip on the door side only.
Create an equal gap between the door and frame at the strike location and fasten.
We provide the 50 5 frame at the same price as a 47 4 7 8 to accommodate the larger wall size.
Sleeve the transom mullion over the brackets sleeve the transom mullion over the bracket on each jamb and insert the self drilling screw through the small hole in the transom mullion and into the pre drilled hole in the bracket.
Length of screws must be sufficient to penetrate into steel stud by at least 1 2 and into wood stud at least 1.
Timely industries is the leading manufacturer of prefinished steel door frames outperforming other door frames with lower opening costs.
Timely industries products pages present complete specifications and details about our prefinished steel door frames.
Prefinished steel door frames.
3 piece kd knocked down frame.
1 3 4 door 3 face header use with sub frame for cmu application 3 face no stop header use with standard frame for concealed overhead closer installation 3 face insert use for sub frame at head with standard frame in cmu glass stop or door panel can be applied to one or both sides of any mullion or jamb.
Create an equal gap between the door and frame at the bottom of the strike jamb and fasten.
This creates instant wall growth.
Apply casing to the trim kit using the same method as timely s standard frame.
This page is the overview of all frames.
Like hollow metal drywall frames timely frames are installed in walls constructed with either wood stud or steel stud framing but are installed after the the drywall is applied and painted.
2 from any end.
Beginning at the head center the header casing in the opening and snap it over one clip in the center.
No painting time and money saved.
All frames that are fire rated require a fire label.
Frame meets u b c 7 2 97 ul 10 c ul 1784 smoke rating cbc 7 2 1998 part 1 2.
A division of s d s.
Minimum 6 drywall screws recommended.
Prefinished steel door frames.
Corporate office 818 492 3500 or.